Elektromotory LOHER – nejlepší ceny v České republice, poptávky
prosím zasílejte na adresu: obchod@vyboelectric.eu
LOHER CHEMSTAR
Flexibility – Adaptation – Optimum

Elektromotor LOHER CHEMSTAR – Ex d(e)
| Surface cooled (t.e.f.c.) | Water cooled | Braking motors | |
|---|---|---|---|
| Motors: | 1PS5 (LOHER CHEMSTAR) Loher name: DN.. | 1PS5 (LOHER CHEMSTAR) Loher name: DNWW | 1PS5 (LOHER CHEMSTAR) Loher name: DB.. |
| Shaft heights: | Frame sizes 071 – 355 mm | Frame sizes 160 – 315 mm | Frame sizes 080 – 200 mm |
| Power range: (50 Hz types) |
Up to 460 kW (thermally utilized to temperature class B at TU = 40 °C) | Up to 500 kW (thermally utilized according to temperature class B TU= 40 °C) | Up to 30 kW for braking torques from 10 to 270 Nm |
| Number of poles: | 2 – 8 pole; also higher pole numbers for special versions
Pole changing: |
2 – 8 pole possible on request |
4 – 8 pole possible on request |
| Voltage range: | Low voltage up to 1000 V | ||
| Rated voltages: | All of the usual low voltages and voltage ranges acc. to IEC 60038
However, also: Non-standard voltages and / or frequencies according to customer specifications |
||
| Operating mode: | S1 and various | ||
| Degree of protection: | IP55, IP56, to IP66 | IP55, IP56, IP66 (higher degrees of protection on request) | up to IP66 |
| Cooling type: | IC 411, IC 416, however, also special cooling types such as e.g. non-ventilated IC | IC 71 W | IC 411, IC 416 |
| Type of construction: | IM B3, IM B6, IM B7, IM V6 IM B5, IM V3, IM V1, IM V5, IM B35, IM V15, IM B14, IM B34, IM V18, IM V19 |
IM B3, IM V5, IM V6, IM B5, IM V1, IM V3 Special types of construction possible on request |
IM B3, IM V5, IM V6, IM B5, IM V1, IM V3, IM B35, IM V15, IM V36 Special types of construction possible on request |
| Enclosure: | Gray cast iron | ||
| Bearings: | Ball bearings (standard) and special bearings for high axial (thrust) and radial forces | ||
| Regulations: | IEC, EN, DIN, VDE | ||
| Types of protection: | „d“ as well as dust explosion protection according to EN 50281-1-1 / EN 50281-1-2 | „d“ | „d“ as well as dust explosion protection according to EN 50281-1-1 / EN 50281-1-2 |
| Noise level: | All motors are noise-optimized (noise limit values according to EN 60034-9), low-noise version possible for 2-pole motors (GG3) | All motors are noise-optimized (noise limit values according to EN 60034-9) | |
Elektromotor LOHER CHEMSTAR – Ex d(e)